Rope Rescue/Equipment/Need/I-beam rigging clamps

From PCSAR

< Rope Rescue | Equipment | Need(Difference between revisions)
Jump to: navigation, search
(Potentially suitable)
Current revision (22:09, 12 April 2011) (edit) (undo)
(Need)
 
(8 intermediate revisions not shown.)
Line 2: Line 2:
I-beam rigging clamps
I-beam rigging clamps
* for training at Fire Hall
* for training at Fire Hall
 +
*: [[Image:Members:Wuth-imgp1023.jpg|300px]]
** sloped I-beams, flange 4 inches wide
** sloped I-beams, flange 4 inches wide
*** '''need to determine flange thickness'''
*** '''need to determine flange thickness'''
-
*** '''determine slope angle'''
+
*** exterior roof has 12 degrees slope; interior ceiling has 2 angles: the edges are greater, the center less (where we will be working)
** horizontal I-beams, flange approx 7-8 inches wide
** horizontal I-beams, flange approx 7-8 inches wide
*** '''need to determine flange thickness'''
*** '''need to determine flange thickness'''
*** '''more accurately measure flange width'''
*** '''more accurately measure flange width'''
 +
== Requirements ==
== Requirements ==
* adjustable from 4 to 8 inches
* adjustable from 4 to 8 inches
-
* placeable on sloping I-beam
+
* placeable on sloping I-beam up to 12 degree slope
** non-rolling
** non-rolling
* MBS: 40 kN
* MBS: 40 kN
** 2 person load, SSSF, pulley at top
** 2 person load, SSSF, pulley at top
** = 8993 lbf
** = 8993 lbf
-
** WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the WLL is only negligibly less than MBS.
+
** WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the MBS is only negligibly greater than the WLL.
== Product options ==
== Product options ==
Line 67: Line 69:
** 3093 HLL Anchor Clamp
** 3093 HLL Anchor Clamp
*** MBS 14,500 lb
*** MBS 14,500 lb
 +
*** flange width: 4" - 16-5/8"
 +
*** horizontal or vertical I-beam
*** http://www.relsafe.com/ProductDetails.aspx?guid=e8b2c0bf-5765-42c8-b21b-acf04fc19ae5&pid=561&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d2
*** http://www.relsafe.com/ProductDetails.aspx?guid=e8b2c0bf-5765-42c8-b21b-acf04fc19ae5&pid=561&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d2
Line 77: Line 81:
=== Not suitable ===
=== Not suitable ===
-
* rigging chains (require horizontal beam)
+
* rigging chains
 +
** ''require horizontal beam''
** http://www.polarfocus.com/view.php?RCS
** http://www.polarfocus.com/view.php?RCS
-
* http://www.polarfocus.com/view.php?RBC
 
-
** "level beams only"
 
* All Material Handling (AMH)
* All Material Handling (AMH)
Line 87: Line 90:
** http://www.allmaterialhandling.com/aspnet/beamclamps.aspx
** http://www.allmaterialhandling.com/aspnet/beamclamps.aspx
** http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps
** http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps
-
** not rated for live load see [http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps pictures]
+
** ''not rated for live load''
 +
*** see [http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps pictures]
** http://www.stageriggingonline.com/beamclamps.html
** http://www.stageriggingonline.com/beamclamps.html
 +
** http://www.polarfocus.com/view.php?RBC
 +
*** ''level beams only''

Current revision

Contents

[edit] Need

I-beam rigging clamps

  • for training at Fire Hall
    • sloped I-beams, flange 4 inches wide
      • need to determine flange thickness
      • exterior roof has 12 degrees slope; interior ceiling has 2 angles: the edges are greater, the center less (where we will be working)
    • horizontal I-beams, flange approx 7-8 inches wide
      • need to determine flange thickness
      • more accurately measure flange width

[edit] Requirements

  • adjustable from 4 to 8 inches
  • placeable on sloping I-beam up to 12 degree slope
    • non-rolling
  • MBS: 40 kN
    • 2 person load, SSSF, pulley at top
    • = 8993 lbf
    • WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the MBS is only negligibly greater than the WLL.

[edit] Product options

[edit] Potentially suitable



[edit] suitability uncertain

Welded ring


[edit] Not suitable