I-beam rigging clamps
I-beam rigging clamps
* for training at Fire Hall
* for training at Fire Hall
 +
:: [[Image:Members:Wuth-imgp1023.jpg|300px]]
** sloped I-beams, flange 4 inches wide
** sloped I-beams, flange 4 inches wide
*** '''need to determine flange thickness'''
*** '''need to determine flange thickness'''

Revision as of 22:08, 12 April 2011

Contents

Need

I-beam rigging clamps

  • for training at Fire Hall
    • sloped I-beams, flange 4 inches wide
      • need to determine flange thickness
      • exterior roof has 12 degrees slope; interior ceiling has 2 angles: the edges are greater, the center less (where we will be working)
    • horizontal I-beams, flange approx 7-8 inches wide
      • need to determine flange thickness
      • more accurately measure flange width

Requirements

  • adjustable from 4 to 8 inches
  • placeable on sloping I-beam up to 12 degree slope
    • non-rolling
  • MBS: 40 kN
    • 2 person load, SSSF, pulley at top
    • = 8993 lbf
    • WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the MBS is only negligibly greater than the WLL.

Product options

Potentially suitable



suitability uncertain

Welded ring


Not suitable