== Need ==
I-beam rigging clamps
I-beam rigging clamps
* for training at Fire Hall
* for training at Fire Hall
 +
*: [[Image:Members:Wuth-imgp1023.jpg|300px]]
** sloped I-beams, flange 4 inches wide
** sloped I-beams, flange 4 inches wide
*** '''need to determine flange thickness'''
*** '''need to determine flange thickness'''
-
*** '''determine slope angle'''
+
*** exterior roof has 12 degrees slope; interior ceiling has 2 angles: the edges are greater, the center less (where we will be working)
** horizontal I-beams, flange approx 7-8 inches wide
** horizontal I-beams, flange approx 7-8 inches wide
*** '''need to determine flange thickness'''
*** '''need to determine flange thickness'''
*** '''more accurately measure flange width'''
*** '''more accurately measure flange width'''
-
* requirements:
 
-
** adjustable from 4 to 8 inches
 
-
** placeable on sloping I-beam
 
-
*** non-rolling
 
-
** MBS: 40 kN
 
-
*** 2 person load, SSSF, pulley at top
 
-
*** = 8993 lbf
 
-
*** WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the WLL is only negligibly less than MBS.
 
-
possible products:
+
== Requirements ==
 +
* adjustable from 4 to 8 inches
 +
* placeable on sloping I-beam up to 12 degree slope
 +
** non-rolling
 +
* MBS: 40 kN
 +
** 2 person load, SSSF, pulley at top
 +
** = 8993 lbf
 +
** WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the MBS is only negligibly greater than the WLL.
 +
 
 +
== Product options ==
 +
 
 +
=== Potentially suitable ===
* General Clamp Industries
* General Clamp Industries
** http://www.superclamp.com/
** http://www.superclamp.com/
** GCI Swivel-Jaw Adjustable Girder Clamp
** GCI Swivel-Jaw Adjustable Girder Clamp
-
*** For use at up to 15° from vertical
+
*** For use at up to 15° from horizontal
 +
**** ''website says: from vertical''
*** Approved for Personnel tie-off use*
*** Approved for Personnel tie-off use*
*** [http://www.superclamp.com/images/ProductsImages_Swivel.jpg picture]
*** [http://www.superclamp.com/images/ProductsImages_Swivel.jpg picture]
Line 31: Line 37:
***** WLL: 22,400 lb
***** WLL: 22,400 lb
** GCI Fixed-Jaw Adjustable Girder Clamp
** GCI Fixed-Jaw Adjustable Girder Clamp
-
*** For use at up to 15° from, vertical
+
*** For use at up to 15° from horizontal
 +
**** ''website says: from vertical''
*** Approved for Personnel tie-off use*
*** Approved for Personnel tie-off use*
*** [http://www.superclamp.com/images/ProductsImages_Fixed.gif picture]
*** [http://www.superclamp.com/images/ProductsImages_Fixed.gif picture]
Line 62: Line 69:
** 3093 HLL Anchor Clamp
** 3093 HLL Anchor Clamp
*** MBS 14,500 lb
*** MBS 14,500 lb
-
**** but manual says 6,000 lb
+
*** flange width: 4" - 16-5/8"
 +
*** horizontal or vertical I-beam
*** http://www.relsafe.com/ProductDetails.aspx?guid=e8b2c0bf-5765-42c8-b21b-acf04fc19ae5&pid=561&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d2
*** http://www.relsafe.com/ProductDetails.aspx?guid=e8b2c0bf-5765-42c8-b21b-acf04fc19ae5&pid=561&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d2
-
** LockJaw Remote Beam Grip Clamp
 
-
*** ''min width 5 inch''
 
-
*** rated 10,000 lb - 2 man load
 
-
*** http://www.relsafe.com/ProductDetails.aspx?guid=485b7f80-88b9-46a2-8ae9-d8eeb47cf0f5&pid=555&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d0
 
-
*** http://www.gravitec.com/equipment/anchors/reliance-lockjaw-remote-beam-grip-clamp/anc-re-3040-1/
 
-
 
-
 
-
 
-
* Beam Clamp (unclear manufacturer)
 
-
** 3 - 9" flange widths
 
-
** WLL, Personal 2,000 lbf.
 
-
** http://www.rescuetech1.com/beamclamp.aspx
 
-
 
-
suitability uncertain:
+
=== suitability uncertain ===
Welded ring
Welded ring
Line 84: Line 79:
-
Not suitable:
+
=== Not suitable ===
-
* rigging chains (require horizontal beam)
+
* rigging chains
 +
** ''require horizontal beam''
** http://www.polarfocus.com/view.php?RCS
** http://www.polarfocus.com/view.php?RCS
-
* http://www.polarfocus.com/view.php?RBC
 
-
** "level beams only"
 
* All Material Handling (AMH)
* All Material Handling (AMH)
Line 96: Line 90:
** http://www.allmaterialhandling.com/aspnet/beamclamps.aspx
** http://www.allmaterialhandling.com/aspnet/beamclamps.aspx
** http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps
** http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps
-
** not rated for live load see [http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps pictures]
+
** ''not rated for live load''
 +
*** see [http://winchlines.com/merchant.mvc?Screen=CTGY&Store_Code=WINCHLINES&Category_Code=Beam_Clamps pictures]
** http://www.stageriggingonline.com/beamclamps.html
** http://www.stageriggingonline.com/beamclamps.html
 +
** http://www.polarfocus.com/view.php?RBC
 +
*** ''level beams only''
Line 107: Line 104:
*** Ideal for Vertical or Horizontal I-Beam Structures.
*** Ideal for Vertical or Horizontal I-Beam Structures.
*** Rated at over 5,000 lbs.
*** Rated at over 5,000 lbs.
 +
*** ''no detailed strength rating''
*** Meets OSHA and ANSI Requirements.
*** Meets OSHA and ANSI Requirements.
*** http://www.falltech.com/productLS.asp?prodID=265
*** http://www.falltech.com/productLS.asp?prodID=265
Line 148: Line 146:
* General Clamp Industries
* General Clamp Industries
** GCI Universal Superclamp
** GCI Universal Superclamp
-
*** '''min flange size: 6 inch'''
+
*** ''min flange size: 6 inch''
*** Can be Loaded at Any Angle
*** Can be Loaded at Any Angle
**** This model is designed to be used at full rated capacity at angles up to 90° in a 360° radius.
**** This model is designed to be used at full rated capacity at angles up to 90° in a 360° radius.
Line 172: Line 170:
*** http://www.relsafe.com/ProductDetails.aspx?guid=afa7f5cc-699f-401d-81b3-356d5b4c3a73&pid=908&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d0
*** http://www.relsafe.com/ProductDetails.aspx?guid=afa7f5cc-699f-401d-81b3-356d5b4c3a73&pid=908&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d0
**** '''wrong manual on web page; cannot determine strength rating'''
**** '''wrong manual on web page; cannot determine strength rating'''
 +
** LockJaw Remote Beam Grip Clamp
 +
*** ''min width 5 inch''
 +
*** rated 10,000 lb - 2 man load
 +
*** http://www.relsafe.com/ProductDetails.aspx?guid=485b7f80-88b9-46a2-8ae9-d8eeb47cf0f5&pid=555&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d0
 +
*** http://www.gravitec.com/equipment/anchors/reliance-lockjaw-remote-beam-grip-clamp/anc-re-3040-1/
 +
 +
* Beam Clamp (unclear manufacturer)
 +
** 3 - 9" flange widths
 +
** WLL, Personal 2,000 lbf.
 +
** WLL, Equipment 4,000 lbf.
 +
** http://www.rescuetech1.com/beamclamp.aspx

Current revision

Contents

[edit] Need

I-beam rigging clamps

  • for training at Fire Hall
    • sloped I-beams, flange 4 inches wide
      • need to determine flange thickness
      • exterior roof has 12 degrees slope; interior ceiling has 2 angles: the edges are greater, the center less (where we will be working)
    • horizontal I-beams, flange approx 7-8 inches wide
      • need to determine flange thickness
      • more accurately measure flange width

[edit] Requirements

  • adjustable from 4 to 8 inches
  • placeable on sloping I-beam up to 12 degree slope
    • non-rolling
  • MBS: 40 kN
    • 2 person load, SSSF, pulley at top
    • = 8993 lbf
    • WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the MBS is only negligibly greater than the WLL.