== Need ==
I-beam rigging clamps
I-beam rigging clamps
* for training at Fire Hall
* for training at Fire Hall
Line 7: Line 8:
*** '''need to determine flange thickness'''
*** '''need to determine flange thickness'''
*** '''more accurately measure flange width'''
*** '''more accurately measure flange width'''
-
* requirements:
+
== Requirements ==
-
** adjustable from 4 to 8 inches
+
* adjustable from 4 to 8 inches
-
** placeable on sloping I-beam
+
* placeable on sloping I-beam
-
*** non-rolling
+
** non-rolling
-
** MBS: 40 kN
+
* MBS: 40 kN
-
*** 2 person load, SSSF, pulley at top
+
** 2 person load, SSSF, pulley at top
-
*** = 8993 lbf
+
** = 8993 lbf
-
*** WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the WLL is only negligibly less than MBS.
+
** WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the WLL is only negligibly less than MBS.
-
possible products:
+
== Product options ==
 +
 
 +
=== Potentially suitable ===
* General Clamp Industries
* General Clamp Industries
Line 65: Line 68:
-
* Beam Clamp (unclear manufacturer)
+
=== suitability uncertain ===
-
** 3 - 9" flange widths
+
-
** WLL, Personal 2,000 lbf.
+
-
** http://www.rescuetech1.com/beamclamp.aspx
+
-
 
+
-
 
+
-
suitability uncertain:
+
Welded ring
Welded ring
Line 77: Line 74:
-
Not suitable:
+
=== Not suitable ===
* rigging chains (require horizontal beam)
* rigging chains (require horizontal beam)
Line 170: Line 167:
*** http://www.relsafe.com/ProductDetails.aspx?guid=485b7f80-88b9-46a2-8ae9-d8eeb47cf0f5&pid=555&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d0
*** http://www.relsafe.com/ProductDetails.aspx?guid=485b7f80-88b9-46a2-8ae9-d8eeb47cf0f5&pid=555&sourceUrl=ProductsByCategory.aspx%3fcategoryId%3d100%26pg%3d0
*** http://www.gravitec.com/equipment/anchors/reliance-lockjaw-remote-beam-grip-clamp/anc-re-3040-1/
*** http://www.gravitec.com/equipment/anchors/reliance-lockjaw-remote-beam-grip-clamp/anc-re-3040-1/
 +
 +
* Beam Clamp (unclear manufacturer)
 +
** 3 - 9" flange widths
 +
** WLL, Personal 2,000 lbf.
 +
** WLL, Equipment 4,000 lbf.
 +
** http://www.rescuetech1.com/beamclamp.aspx

Revision as of 17:01, 19 March 2011

Contents

Need

I-beam rigging clamps

  • for training at Fire Hall
    • sloped I-beams, flange 4 inches wide
      • need to determine flange thickness
      • determine slope angle
    • horizontal I-beams, flange approx 7-8 inches wide
      • need to determine flange thickness
      • more accurately measure flange width

Requirements

  • adjustable from 4 to 8 inches
  • placeable on sloping I-beam
    • non-rolling
  • MBS: 40 kN
    • 2 person load, SSSF, pulley at top
    • = 8993 lbf
    • WLL is not the same as MBS. It has a Design Factor (DF) built in for safety. That factor is not documented; OSHA talks about factor 2 in other parts of its standard. But without specification, we assume that the WLL is only negligibly less than MBS.

Product options

Potentially suitable




suitability uncertain

Welded ring


Not suitable